The AV-FP range of economical airflow sensors sense differential (velocity) pressure of VAV units and other locations in main or branch ducts.
Description
The AV-FP range of economical airflow sensors sense differential (velocity) pressure of VAV units and other locations in main or branch ducts. Four different lengths allow the selection of the sensor to yield accurate readings on terminal unit inlet diameters from 100mm to 500mm.
The sensor operates by measuring the velocity pressure using a differential pressure transmitter such as the PTH-3202.
Specification
Mounting: Integral flange with gasket.
Connections: ¼” nipples for ⅜” OD polyethylene tubing.
Ambient: 0°C to 50°C
BMS Parts PDF Download
The Series PAFS-1000 Averaging Flow Sensor is ideal for measuring differential pressure in the inlet section of variable-air-volume terminal units and fan terminal units. Units can also be used to sense differential pressure at other locations in the main or branch duct systems.
The “H” port senses total pressure, and the “L” port senses static pressure. The difference between these signals is the differential, or velocity pressure.
Models offer up to 10 sensing points and lengths ranging from 3-5/32″ to 23-29/32″ (8.02 to 60.72 cm), accommodating box sizes from 4″ to 30″ (10.16 to 76.20 cm).
INSTALLATION
The Series PAFS-1000 utilises 1/4″ ID, 3/8″ OD tubing. First, check that there are no sharp bends in the tubing at any connection. Bends and creases may leak over time as the tubing ages.
Connect the “H” Port to the high input on the differential pressure gauge. transmitter, or switch.
Connect the “L” Port to the low input on the differential pressure gauge. transmitter, or switch.
Approximate K factors for models:
PAFS-1002: 1.32
PAPS-1003: 1.39
PAFS-1004: 1.46
PAPS-1005: 1.46
PAPS-1006: 1.58
PAFS-1007: 1.67
PAPS-1008: 1.78
PAPS-1009: 1.88
PAFS-1010: 2.01
PAFS-1011: 2.14
It may be necessary to calibrate to ensure accurate measurement. You can do this by traversing the duct or fan to determine the PAPS-sensed delta P vs. the actual flow.
MOUNTING
- Install the unit horizontally to assure accurate velocity readings for units ranging from 3-5/32″ to 9-29/32″. If using a unit longer than the PAPS-1005, which is 0- 29/32-, vertical mounting is recommended.
- Determine the duct’s flow direction and install the Series PAPS-1000 based on the unit’s flow arrow imprint.
- Cut a 7/8″ hole in the ducting to accept the unit.
- Attach using two self-tapping screws inserted in the 3/16″ mounting holes.
Model Number of Sensing Points Sensor Length
PAPS-1002 3-5/32- (8.02 cm)
PAFS-1003 5-13/32″ (13.73 cm)
PAFS-1004 7-21/32″ (19.55 cm)
PAFS-1005 9-29/32″ (25.26 cm)
PAFS-1006 12-1/2- (31.75 cm) – Email for Price
PAFS-1007 14-3/4″ (37.47 cm) – Email for Price
PAPS-1008 17-1/8- (43.50 cm) – Email for Price
PAFS-1009 19-13132- (49.29 cm) – Email for Price
PAFS-1010 21-21/32″ (55.01 cm) – Email for Price
PAFS-1011 23-29/32- (60.72 cm) – Email for Price
SPECIFICATIONS
Service: Air and compatible gases.
Wetted Materials: ABS/polycarbonate (1JL94-5V).
Temperature Limits: Operating: 40 to 120°F (4 to 49°C);
Storage: -40 to 140°F (-40 to 60°C).
Connection: 1/4″ (6 mm) ID, 3/8″ (10 mm) OD tubing.
Mounting Orientation: Integral flange with gasket.
Weight: 1 oz (28 g).
MAINTENANCE
Sensing orifices must be kept free of dust accumulation or debris. Occasional cleaning may be required.
Upon final installation of the Series PAPS-1000 Averaging Flow Sensor, no routine maintenance is required. Periodic checks of system calibration are recommended. The Series PAPS-1000 is not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty).
Be sure to include a brief description of the problem plus any relevant application notes.
Contact customer service to receive a return goods authorisation number before shipping.
| Weight | 0.26 kg |
|---|---|
| Length | 80mm, 140mm, 195mm, 250mm |
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
You may also like…
Clear PVC Flexible Hose Pipe 5mm ID – 7mm OD for Pitot Tubes
Duct Connection Set
Multi Range Pressure Transducer
PTH is a series of pressure transducers that are ideal for monitoring and controlling pressure differentials in ventilation systems.
PTH transducers take up very little space and are designed for direct installation at the measuring point and are also compact and easy to install as there is ample room for attaching cables.
Related products
Air Velocity Transmitter 0/16 m/s – 0-10Vdc – AVS-16
Room Pressure Nipple
Single Point Duct Air Velocity Sensor 0…4 m/s – 0…10Vdc output – AV-4
ST/ST Multi-point Velocity Probe
The AV-MP range of Air Velocity Pitot Tubes can be used with our ranges of Air Differential Pressure Sensors to calculate airflow in larger ducts or in areas of turbulent airflow.

Reviews
There are no reviews yet.