EB-306 Current Bar
£265.00 Exc. VAT
The EC is a current sensor for standard miniature circuit breakers (MCB). It is designed to fit any type of IEC standard MCB, Residual-Current Devices (RCD), and Residual-current Circuit Breakers with Overload protection (RCBO) capable of measuring devices up to 40A. The EC includes a current transformer (CT) with turn ratio of 1:1000 and a burden resistor of 10Ω. The EC does not interfere with or affect the function of the MCB.
The EB-306 Current Bar is a modular current meter formed of 2 parts:
- The bar (With Lable) itself is a Modbus-enabled meter and is available in three different sizes, supporting a max of 6 input channels.
- Current Sensors (6 x CTs) are pre-assembled with the EB Current Bar.
The EC is a current sensor for standard miniature circuit breakers (MCB).
It is designed to fit any type of IEC standard MCB, Residual-Current Devices (RCD), and Residual-current Circuit Breakers with Overload protection (RCBO) capable of measuring devices up to 40A.
The EC includes a current transformer (CT) with a turn ratio of 1:1000 and a burden resistor of 10Ω.
The EC does not interfere with or affect the function of the MCB.
- Fitted on top of all EU standard circuit breakers
- Output Values: A, °C (Environmental temperature)
- Device Bus: 12V DC
- Interface Protocol: Modbus RTU – 19200, 8, E, 1 (default settings)
- Available in 3 sizes, 3, 6, and 12 inputs
- mA current transformers (up to 63A)
- Accuracy: +/- 1% of full-scale signal @25°C
-

BMS Parts PDF Download
| Weight | 0.50 kg |
|---|
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Compact IO Module DO-8-C
Invertek Drives 3 Phase IP66
Rich in features the Optidrive E2 is the most commercially competitive Optidrive in the Optidrive family.
LoRa Wireless RS485 transmitter and receiver – 2 Units
The LoRaWAN Data Transmission Terminal is a universal communication interactive equipment that is designed and manufactured based on LoRa RF chip.
It integrates two interfaces of industrial standard RS485 and supports a variety of protocols to realise the data transmission between wired and wireless devices.
It supports LoRaWAN Class C protocol. It can be widely applied in the IoT, centralised metering and industrial control etc.
LoRa Wireless RS485 transmitter or receiver with LCD screen – 1 Unit
The LoRaWAN Data Transmission Terminal is a universal communication interactive equipment that is designed and manufactured based on LoRa RF chip.
It integrates two interfaces of industrial standard RS485 and supports a variety of protocols to realise the data transmission between wired and wireless devices.
It supports LoRaWAN Class C protocol. It can be widely applied in the IoT, centralised metering and industrial control etc.
OB115-MOD Meter with Split CT works with GivEnergy System- Modbus RTU – ID1 Address
Solid Core and Split Core Current Sensors, 0-10, 0-20, 0-50, 0–100, 0-150, 0-200 A, output 0-10VDC or 4-20-mA
The CS series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear  4-20mA or 0 to 10 VDC output signal, which can be monitored by a Building Management System.

Reviews
There are no reviews yet.